AST Protection for Tank Bottom External Surface
Click here for the full brochure
Click here for the ReCAST-SSB FAQ
|
ReCAST-SSB solution deployed on the external surface of an AST bottom. |
Zerust® molecules in the sandbed below the AST bottom working in combination with cathodic protection to efficiently mitigate corrosion. |
Industry Problem:
Pitting corrosion of soil-side bottoms of Aboveground Storage Tanks (ASTs) causes the formation of holes that allows product leakage into the environment. This specific type of corrosion forms in the gaps or “vapor spaces” between the metal tank bottom and the soil/concrete slab it rests on. These “vapor spaces” are formed when the metal bottom flexes up and down when product is filled and removed from the AST. In addition, when the AST is constructed using bituminous beds below the tank bottoms (a common practice), it leads to attack from the acids in the surrounding soil, which seep through these same beds. Because of the leaks caused by corrosion, tank operators have to periodically stop tank operations for repairs or to replacement of the entire bottoms. The stoppage time can come within the first few years of a tank’s life (2 to 4 years), or at scheduled inspection intervals (6 to 10 years depending on relevant API 650 guidelines).
Our Solution:
NTIC has developed an innovative solution, Zerust® ReCAST-SSB, which works as a three-part system combining cathodic protection, volatile corrosion inhibitors, and soluble corrosion inhibitors, providing efficient protection at all times. NTIC monitors the effectiveness of the inhibitors without causing any unscheduled stoppages. This three-part system allows for inhibitor concentrations to be adjusted through an inhibitor delivery system with a delivery station that is installed outside the tank base.
The Zerust® ReCAST-SSB system has been developed to work in such aggressive corrosion environments as illustrated by the key parameters below:
|
Critical Parameter |
Range in Field Applications |
Range in Laboratory Tests |
|
Operating Temperatures, °C |
22 - 45 |
20 - 55 |
|
Relative Humidity, % |
90 - 100 |
60 - 100 |
|
H2S and SO2 , ppm |
<5 - 100 |
20 -100 |
|
O2, % |
4 - 21 |
10 - 21 |
|
Chlorides, ppm |
300 – 1,800 |
300 – 1,800 |
|
Other Inorganic Salts, ppm |
50 - 200 |
50 - 200 |
Actual pitting corrosion pictures taken at a client’s site:
![]() |
![]() |
![]() |
|
CORROSION HOLES IN THE AST BOTTOM |
CORROSION DAMAGE ON THE UPPER BOTTOM PLATES OF THE ABOVEGROUND STORAGE TANK |